Files
notarius/docs/adr/0028-retain-all-diagnostic-groups.md

1.4 KiB

ADR-0028: Retain all diagnostic groups

Status: Accepted Date: 2026-11-25

Context

Fixed local and final diagnostic group caps could fail otherwise valid work or discard non-warning groups. The caps did not represent selected input limits, and truncated collections could not preserve every completed finding.

Decision

Retain all valid diagnostic groups in stable origin-aware order, without local or final group-count caps. Preserve exact checked occurrence totals, at most three distinct samples per group, and the per-group omitted-sample count. Invalid diagnostics and arithmetic overflow still fail. No replacement limit, exhaustive occurrence ledger, or durable report sidecar is introduced.

This supersedes only the group-cap and collection-truncation portions of ADR-0015 and ADR-0024. Their diagnostic classifications and other accepted decisions remain in force.

Alternatives considered

  • Increase or configure the caps: this retains the arbitrary failure or loss boundary without establishing a selected resource policy.
  • Record every occurrence: this adds an exhaustive ledger that is not needed for grouped diagnostic presentation.

Consequences

Group memory grows with distinct findings. Samples remain bounded per group, but the application makes no global group-count or diagnostic-memory guarantee.