diff --git a/docs/roadmap/audit/catalog.md b/docs/roadmap/audit/catalog.md index 7e1d22a6..de042cba 100644 --- a/docs/roadmap/audit/catalog.md +++ b/docs/roadmap/audit/catalog.md @@ -12,8 +12,8 @@ results. This document adds prioritization and cross-report consolidation, not another code audit or an implementation plan. The companion [remediation discussion](discussion.md) collects review -recommendations and open choices in discussion order. Its proposals do not change -the finding statuses or authorize remediation. +recommendations and open choices in discussion order. Accepted decisions there +qualify proposed remediation; finding statuses here track implementation. The **45 original finding entries** reduce to **33 outstanding catalog entries and one resolved documentation entry**. Repeated responsibility findings are @@ -199,6 +199,11 @@ bounded available diagnostics as incomplete failure information, and avoid the duplicate pass. Test the combined failure, preserving existing warning bounds and failure semantics rather than silently truncating warnings into success. +**Subsequent decision:** [Discussion Item 1](discussion.md#1-diagnostic-capacity-and-pipeline-success) +selects removal of diagnostic group-count caps while retaining per-group sampling +and genuine failure causes. That accepted design replaces the warning-bound +preservation recommendation above; implementation remains pending. + ### CAT-010 — Process Signals Do Not Reach Cooperative Cancellation **Assessment:** Static executable integration weakness; original P3. diff --git a/docs/roadmap/audit/discussion.md b/docs/roadmap/audit/discussion.md index 621c9701..5383c1da 100644 --- a/docs/roadmap/audit/discussion.md +++ b/docs/roadmap/audit/discussion.md @@ -10,9 +10,9 @@ and subsequent discussion decisions, not another audit or a completed implementation plan. Prepared on 2026-11-24 against catalog revision -`5a0650250686353cf34fbbbf0e780b04f60e70c1`. All recommendations below remain -proposals. No remediation or policy change is approved merely by its inclusion -here. Record decisions in the corresponding item as discussion proceeds. +`5a0650250686353cf34fbbbf0e780b04f60e70c1`. Each item distinguishes accepted +decisions from proposals still under discussion. Acceptance selects the intended +design; implementation remains pending unless explicitly recorded otherwise. The review supports the existing typed pipeline and native-kit architecture. The strongest opportunities are removing repeated interpretation, unnecessary @@ -28,37 +28,50 @@ order, and unresolved choices need not delay independent fixes. ## 1. Diagnostic Capacity And Pipeline Success **Findings:** CAT-009; related CAT-008 and CAT-022. -**Status:** Open behavior decision. +**Status:** Accepted; implementation pending. CAT-009 identifies a real loss of aggregation errors and available diagnostics. Its suggested remediation also preserves the existing policy that exceeding the warning-group bound can fail an otherwise successful pipeline. These are separate issues: fixing error loss does not require endorsing that policy indefinitely. -The recommendation is to reconsider whether diagnostic volume alone should -invalidate acceptable artifacts. This is particularly relevant to the -artifact-first direction. Possible designs include bounded presentation with an -explicit overflow indication, or removing an unnecessary group-count cap. Neither -should conceal fallback/degradation or suppress genuine execution and diagnostic -contract errors. +**Accepted decisions:** -Questions to settle: +- Diagnostic volume alone does not fail a pipeline. Artifact acceptance continues + to follow the configured validation and strict/permissive decisions. +- Retain every distinct diagnostic group. Remove the local producer group-count + cap and both final warning/non-warning group-count caps. Remove collection-level + truncation and omission bookkeeping used solely to enforce those caps; do not + replace them with configurable limits. +- Retain grouping, occurrence counts, and representative sampling within each + group, initially keeping the existing three-example behavior and omitted-sample + counts. Distinct-group retention does not require storing every occurrence. +- Preserve diagnostics from completed operations when later execution fails, + independently of lane continuation. Incomplete lanes remain ineligible for + artifact publication. +- Preserve genuine diagnostic-contract, arithmetic-overflow, reporting, and + requested-capture failures. When finalization fails, retain the primary and + finalization causes alongside available valid diagnostics. The error can + explain incompleteness; no new report schema or durable sidecar is needed. +- Keep the small completion report, fallback disclosure, and native CommandKit + presentation unchanged. -- Should exceeding a diagnostic capacity limit fail the pipeline? -- If not, should the collection retain all groups or retain a bounded summary - with explicit omitted-information reporting? -- What information must remain available on failure, and how should an incomplete - diagnostic collection be identified without adding another report protocol? +This removes capacity-driven acceptance policy and collection-overflow paths while +preserving useful summaries. Memory grows with distinct groups; grouping and +representative samples still prevent repeated occurrences from requiring one +retained message each. No exhaustive diagnostic ledger is introduced. -The initial preference is against failing acceptable artifact production solely -because diagnostic volume exceeds a reporting limit. This is a proposed policy -change, not authority to silently truncate actionable warnings. Existing bounded -aggregation is retained by [ADR-0015](../../adr/0015-separate-process-warnings-from-quality-diagnostics.md) +Removing group caps eliminates the ordinary capacity-overflow case in CAT-009, +but genuine finalization failures must still retain their causes and available +diagnostics. CAT-008's completed-work diagnostic loss remains a separate fix. + +Existing bounded aggregation is retained by +[ADR-0015](../../adr/0015-separate-process-warnings-from-quality-diagnostics.md) and [ADR-0024](../../adr/0024-publish-artifacts-with-native-reports-and-debug-evidence.md). -Any selected change must be reconciled with those decisions and canonical -documentation when implemented. +Reconcile this accepted change with those architectural decisions and canonical +documentation during implementation, preserving accepted ADR bodies. -**Decision:** Pending. +**Decision:** Accepted as above. No open policy choices remain in this item. ## 2. Convenient Debug Evidence And Repeated Full-Source Capture @@ -172,7 +185,7 @@ That fix need not wait for the broader producer refactor. ## 6. Finalization, Completed Diagnostics, And Intermediate Lifetimes **Findings:** CAT-006, CAT-008, CAT-009, CAT-022; coordinate CAT-023 at the CLI boundary. -**Status:** Open technical design review; overflow policy depends on Item 1. +**Status:** Open technical design review; apply Item 1's accepted diagnostic policy. Design diagnostic collection and lifetime reduction together. Completed work's diagnostics must survive a later failure before its intermediate values are